Federal Match AR primer ??

A quote:

– Cases that utilize small rifle primers and operate at moderate pressures (40,000 psi) can use CCI 400, Federal 200, Rem 6 1/2, or Win SR. Such cases include 22 CCM, 22 Hornet and the 218 Bee. Other cases that use the small rifle primer can use the above primers only if moderate loads are used. Keep to the lower end of reloading recommendations.

– Cases that utilize small rifle primers and operate at higher pressures (55,000 psi) should use CCI 450, CCI BR4, Fed 205 and Rem 7 1/2.

Another factor which determines the strength of a primer cup is the work-hardened state of the metal used to make the primer cup. Most primers are made with cartridge brass (70% copper, 30% zinc), which can vary from 46,000 psi, soft, to 76,000 psi tensile strength when fully hardened. Note that manufacturers specify the hardness of metal desired, so some cups are definitely “harder” that others.
calhoonprimers02.png



I find larger variation in weight (light/heavy outliers) with the #41 primers than with the #450.
 
  • Like
Reactions: DIBBS
Federal Primers in general tend to have softer cups and are more sensitive. The fact that Federal chose to put out these primers would tend to indicate that the cup is stronger to be more resistant to slam fire and fire pin denting which is an AR issue. Whether it is harder or thicker is hard to say as both would tend to achieve the same result. As to compound I suspect it's hotter since they went to the trouble to make it meet mil-spec sensitivity. I would treat it like a Rem 7-1/2 or CCI 41.
 
  • Like
Reactions: simonp
yes, we all 'would'. but are they like that?


Mix is the same as in the standard small rifle primer. The primer cup is thicker, as is the anvil. The thicker cup and anvil "should" desensitize the primer a bit, and "lessen" the chance of a slam-fire. Federal primers are in general, more sensitive than CCI and less tolerant of firing pin blows during loading into the chambers of the M1 Garand, M1-A, and AR platforms.
 
yes, we all 'would'. but are they like that?


Mix is the same as in the standard small rifle primer. The primer cup is thicker, as is the anvil. The thicker cup and anvil "should" desensitize the primer a bit, and "lessen" the chance of a slam-fire. Federal primers are in general, more sensitive than CCI and less tolerant of firing pin blows during loading into the chambers of the M1 Garand, M1-A, and AR platforms.
Just out of curiosity I sent a question to Federal this morning questioning whether to consider the primer as a "standard" or "magnum" and the answer was "standard".

I have to admit that I found that a little surprising.
 
  • Like
Reactions: msgriff
Just out of curiosity I sent a question to Federal this morning questioning whether to consider the primer as a "standard" or "magnum" and the answer was "standard".

I have to admit that I found that a little surprising.
I find it surprising also , I was told "Magnum" to the same question .
 
maybe because federal doesnt have magnum SR primers.
That's true. And the reality is it's probably not needed for the case capacities that the SR primers are normally used in.

Somewhere in the back of my mind I remember reading that there was an issues with primers and ignition and the solution was to add material that added particles to compound to help ignition. May have been in Hatcher's Notebook.
 
With my loads for the AR I found zero difference with my 75/77 8208 load using the regular Fed Match and AR match. I never had any issues with the regular match primers with slam fires or any problems at all. I have both and interchange depending on the box I grab that day.